Residual myocardial dyssynchrony after cardiac resynchronization therapy in patients with and without immediate echocardiographic optimization

    Authors

    Keywords

    cardiac resynchronization therapy, dyssynchrony, echocardiographic optimization

    DOI

    https://doi.org/10.15836/ccar2021.202

    Full Text

    Introduction : Cardiac resynchronization therapy (CRT) is used in the treatment of severe symptomatic heart failure with LBBB. Such patients often have at least one echocardiographic sign of either one type of dyssynchrony, interventricular (VV), intraventricular or atrioventricular (AV), present. It is known that about 30% of patients are nonresponders to this type of treatment. One of the causes is residual dyssynchrony after CRT device implantation. ( 1 , 2 ) The aim of this study was to determine whether there is a difference in the presence of any of the echocardiographic signs of dyssynchrony after 6 months of follow up using two different CRT optimization methods. Patients and Methods : We included 147 CRT patients in this study. Each patient underwent full echocardiographic study with assessing signs of dyssynchrony before and 6 months after CRT device implantation. Patients were divided into two groups according to the method of CRT optimization, echocardiographically (ECHO) or electrocardiographically (ECG) guided CRT optimization. In Both groups initially AV and VV delay optimization were set up according to QRS width. On top of this ECHO group was additionally echocardiographically optimized accordingly to echocardiographic signs of dyssynchrony, septal flash (SF) disappearance, A wave truncation and merged E and A waves (AVd) and interventricular mechanical delay (IVMD). After 6 months of follow up residual dyssynchrony was defined as presence of SF, AVd and/or IVMD >40 ms. Results : In both groups, a significant reduction of echocardiographic signs of dyssynchrony was observed during the follow-up period. Comparison between the groups showed that residual SF and AVd were less frequent present in the ECHO group and reached statistically significance (p<0.01 for SF and AVd) while IVMD reduction did not differ between groups (p=0.84) ( Table 1 ). Conclusion : Echocardiographic optimization of CRT is associated with a greater reduction of residual SF and AV dyssynchrony compared to ECG optimization while no difference in the reduction of IVMD was observed between analyzed groups 6 months after CRT.

    Cardiologia Croatica
    Back to search

    Residual myocardial dyssynchrony after cardiac resynchronization therapy in patients with and without immediate echocardiographic optimization

    Extended Abstract
    Issue5-6
    Published
    Pages202
    PDF via DOIhttps://doi.org/10.15836/ccar2021.202
    cardiac resynchronization therapy
    dyssynchrony
    echocardiographic optimization

    Authors

    Marija Brestovac*ORCIDUniversity of Zagreb School of Medicine, Zagreb, Croatia
    Blanka Glavaš KonjaORCIDUniversity of Zagreb School of Medicine, Zagreb, Croatia
    Martina Lovrić BenčićORCIDUniversity of Zagreb School of Medicine, Zagreb, Croatia
    Vlatka Rešković LukšićORCIDUniversity of Zagreb School of Medicine, Zagreb, Croatia
    Kristina GašparovićORCIDUniversity of Zagreb School of Medicine, Zagreb, Croatia
    Sandra Jakšić JurinjakORCIDUniversity of Zagreb School of Medicine, Zagreb, Croatia
    Jadranka Šeparović HanževačkiORCIDUniversity of Zagreb School of Medicine, Zagreb, Croatia

    Full Text

    Introduction : Cardiac resynchronization therapy (CRT) is used in the treatment of severe symptomatic heart failure with LBBB. Such patients often have at least one echocardiographic sign of either one type of dyssynchrony, interventricular (VV), intraventricular or atrioventricular (AV), present. It is known that about 30% of patients are nonresponders to this type of treatment. One of the causes is residual dyssynchrony after CRT device implantation. ( 1 , 2 ) The aim of this study was to determine whether there is a difference in the presence of any of the echocardiographic signs of dyssynchrony after 6 months of follow up using two different CRT optimization methods. Patients and Methods : We included 147 CRT patients in this study. Each patient underwent full echocardiographic study with assessing signs of dyssynchrony before and 6 months after CRT device implantation. Patients were divided into two groups according to the method of CRT optimization, echocardiographically (ECHO) or electrocardiographically (ECG) guided CRT optimization. In Both groups initially AV and VV delay optimization were set up according to QRS width. On top of this ECHO group was additionally echocardiographically optimized accordingly to echocardiographic signs of dyssynchrony, septal flash (SF) disappearance, A wave truncation and merged E and A waves (AVd) and interventricular mechanical delay (IVMD). After 6 months of follow up residual dyssynchrony was defined as presence of SF, AVd and/or IVMD >40 ms. Results : In both groups, a significant reduction of echocardiographic signs of dyssynchrony was observed during the follow-up period. Comparison between the groups showed that residual SF and AVd were less frequent present in the ECHO group and reached statistically significance (p<0.01 for SF and AVd) while IVMD reduction did not differ between groups (p=0.84) ( Table 1 ). Conclusion : Echocardiographic optimization of CRT is associated with a greater reduction of residual SF and AV dyssynchrony compared to ECG optimization while no difference in the reduction of IVMD was observed between analyzed groups 6 months after CRT.